Chlorine institute pamphlet 6 pdf

Chlorine institute pamphlet 6 rewrite task group chemflow. Ci publishes regulatory updates every month for members highlighting news affecting the chloralkali industry, including proposed rules, open comment periods, interpretations on existing rules, voluntary programs, newly published resources, training opportunities, and agency directives. Chlorine institute members are committed to adopting ci safety and. Chlorine institutes pamphlet 96 with the permission of the chlorine institute. The first chlorine manual was published by the chlorine institute in 1947. The chlorine institute publishes several pamphlets on the safe handling of chlorine, and recommends materials, practices, and design features. Chlorine transfer hose assemblies hose master chlorsafe.

Pamphlet 6 piping systems for dry chlorine sphp0006hc. Pamphlet 96 also contains additional information on sodium hypochlorite. Ci pamphlet 6, piping systems for dry chlorine, gives recommendations on valve construction. Chlorine piping and cleaning information nitrogen purging. Jamesbury valve solutions for chloralkali processing.

Scribd is the worlds largest social reading and publishing site. Cl2 hose assemblies are 100% compliant with the chlorine institutes pamphlet 6. The reader is referred to institute publication pamphlet 7 12. The user should ascertain that the personal protective equipment is suitable for protecting personnel from the chemicals being handled and at the concentrations encountered. Opening a liquid chlorine valve too rapidly could cause the excess flow. Cl2 hose consists of bwo layers of high pressure rated pvdf kynaro braid that is. It is part of the chlorine institutes support of the chloralkali industry and service to the public. Page 5 of 32 t h e h i s t o r y a n d g r o w t h o f c h l o r i n e the earliest annals of chemistry mention chlorine compounds. Cichlor pamphlet 17 packaging plant safety and operational. Chlorine chlor alkali valve figure numbers based on chlorine.

Pamphlet 6 piping systems for dry chlorine ci pipe. Chlorine institute pamphlet 6 class ii requirement. For further information regarding caustic soda and chlorine, refer to the appropriate oxychem handbook. Av products informational pamphlets wall charts 2018 ci catalog. Chlorine institute are encouraged to test new gaskets and gasket materials following the procedures in pamphlet 95. Pamphlet 1 chlorine basics hawaii department of agriculture. Among the 21 other publications already free for download is the highly respected chlorine manual pamphlet 1, which is an approved american national standards institute ansi standard, and has served as the bible for chlorine operations since the first edition was published in 1947. Chlorine institute pamphlet 6 rewrite chlorine institute pamphlet 6 the chlorine institute publishes pamphlets that provide guidance on the safe production, storage, transportation and handling of chlorine, a chemical broadly used in the manufacturer of plastics, specialty chemicals, agricultural chemicals and water treatment. About ci mission 2 xyz the chlorine institute 2018 catalog. The pamphlet includes practical design options for a variety of industry accepted systems. Contains information on selected pipe, valves and fittings suitable for use with dry chlorine gas or liquid within the range of 150 degrees f and 300 degrees f. The lbr series valves are designed to offer longterm maintenancefree security against the harmful effects of fugitive emissions. There is also guidance on preparations for use and maintenance practices.

Chlorine institute emergency kit b and this instruction booklet are made available by the chlorine institute, inc. Provides instructions and illustrates the use of chlorine institute emergency kit a this booklet provides instructions for both generations of emergency kit a, those manufactured before 123112 and after 11. Preventing corrosion under insulation cui a chlorine. Chlorine meets the chlorine institute pamphlet 6 recommendations 59 piping systems for dry chlorine maximum working pressure psig minimum bend radius gas test pressure psig. At the beginning of section 10 selected references, complete.

Pamphlets 10 and 72 are not included in this program but are still available for purchase through the bookstore. Chlorine institute members are committed to adopting cis safety and stewardship initiatives, including pamphlets, checklists, and incident sharing, that will assist members in achieving measurable improvement. I have one piping class in ltcs material which is to be used for chlorine gas service. The contents of this pamphlet are not to be copied for publication, in whole or part, without prior chlorine institute permission. With edition 7 of pamphlet 1 2008, the chlorine manual was renamed chlorine basics. Health and environmental effects, and other sources believed to. These checklists are being added to new and existing pamphlets beginning in 1996.

Report pamphlet 6 piping systems for dry cl2 your name. Angle valve guidelines for chlorine bulk transportation. A securely attached tag designating the valve has been cleaned and tested for chlorine service in accordance with chlorine institute pamphlet 6 will be used by manufacturers to indicate the valve has been prepared for service. The institutes health, environment, safety, and security issue team approved edition 5 of this pamphlet on november 5, 2010. In 1798, tennant of england prepared a solution of calcium hypochlorite by. The chlorine institute is adding checklists to appropriate pamphlets to. Chlorine uses and properties chlorine has a wide variety of uses, but one of its primary uses is in the disinfection of water and wastewater. References hlorine institute publications referenced in this publication are referred to by pamphlet number, drawing number, or by condensed name if no number exists. The chlorine institute ci founded in 1924, is a technical trade association of companies involved in the safe production, distribution and use of chlorine, sodium and potassium hydroxides and sodium hypochlorite, the distribution and use of hydrogen chloride and the distribution of vinyl chloride monomer. S ubsequent to the successful completion of a one year test, the member comp an y reports the results to the institute so that the results can be added to the chlorine institute gasket tables found in pamphlet 95. Chlorine applications chlorine transfer hose specifications. Nitrogen purging chlorine gas and liquid pressure piping. Chlorine piping and cleaning information nitrogen purging chlorine gas and liquid pressure piping. Chlorine service ball valves flowserve corporation.

Chlorine jamesbury chlor alkali valve figure numbers based on chlorine institute pamphlet 6 valve service table application report class i service class class ii class iii class iv class v class vi ball valves class 150 bulletin b1071 oa oa oa nr nr nr nr oa nr 1 3 7300l1 31 2671 xtz4 1 3 7300l1 31 2673 xtz4 bulletin b1154 1 3. M c h l o r i n e h a n d b o o k occidental petroleum. The chlorine institute contacted known vendors of these. Cichlor pamphlet 17 packaging plant safety and operational guidelines published by cichlor on november 1, 2017 the purpose of this pamphlet is primarily to provide both operational recommendations and safety information for employees at facilities that package 100 lb. This pamphlet remains a valued resource, providing basic information for general users and providing an overview and references to more detailed information in other publications available from the chlorine institute. Chlorsafe assemblies are manufactured in compliance with the chlorine institute pamphlet 6, appendix a, latest edition. Chlorine institute ci standards and technical documents. The institutes customer stewardship issue team approved edition 2 of this pamphlet on january 3, 2008. Pamphlet 6 piping systems for dry cl2 pdf free download. Pamphlet 6 piping systems for dry cl2 free download as pdf file. Contains information on selected pipe, valves and fittings suitable for use with dry chlorine gas or liquid within the range of 150. The principal target audiences for this pamphlet are. Monel 400 hose and braid meets chlorine institute specifications fully tested and prepared for shipping tough demanding applications such as chlorine transfer require a precision fabricated hose assembly that meets the requirements of the chlorine institute pamphlet 6. Comprehensive foundry qualification and cast component quality program ensures metallurgy is consistent with astm material requirements.

Chlorine service ball valves technical bulletin no. Manufactured in accordance with chlorine institute pamphlet 6. Pamphlet 85 recommendations for prevention of personnel injuries for chlorine production and use facilities edition 5 november, 2010 chlorine institute pamphlet 85 the chlorine institute, inc. Pamphlet 6 piping systems for dry chlorine ci free download as pdf file. This instruction booklet provides information on the design and use of the chlorine institute emergency kit b.

Subsequent to the successful completion of a one year test, the member company reports the results to the institute so that the results can be added to the. History and growth of chlorine 5 production process 6 characteristics 7 chlorine containertank trucks 8 chlorine containersrail cars 9 handling equipment 12 safety and emergency information 14 technical data 17 bibliography 29 chlorine institute 30 table of contents. Pamphlet 96 sodium hypochlorite manual contains information for the safe production, handling and use of both industrial and household strength bleach solutions. Chlorine institute emergency kit b for chlorine ton. The contents of this pamphlet are not to be copied for publication, in whole or in part, without prior institute permission. May 02, 2018 download pamphlet 6 piping systems for dry chlorine ci. Chlorine institute pamphlet 95 gaskets for chlorine service. For over 50 years the chlorine institute standard angle valve has effectively served the needs of bulk chlorine shippers throughout north america. This support extends to giving continued attention to the security of chlorine handling operations. Pamphlet 6 piping systems for dry chlorine sphp0006hc contains information on selected pipe, valves and fittings suitable for use with dry chlorine gas or liquid within the range of 150 degrees f and 300 degrees f. It was a comprehensive compilation of information to assist chlorine producers, packagers, and. Because of the toxicity of chlorine, the chloralkali industry has established strict safety measures for the handling of chlorine under normal circumstances, process upset, or disrupted conditions. Pamphlet 6 piping systems for dry chlorine click to show enlarged image below contains information on selected pipe, valves and fittings suitable for use with dry chlorine gas or liquid within the range of 150 degrees f and 300 degrees f.

The chlorine institute encourages the use of the pamphlets and their checklists. The chlorine institute does not approve, rate, certify, or endorse any product or. This pamphlet describes what are believed to be safe methods for carrying out the numerous operations of a chlorine packaging plant. As recommended by the chlorine institutes pamphlet 6 piping systems for dry chlorine, all pressurized piping should be seamless carbon steel, grade b, schedule 80, type s, astm a106. Information in this brochure is drawn from chlorine institute pamphlet 90, molecular chlorine. Health and environmental effects, and other sources believed to be reliable. These valves are designed to comply with recommendations from the chlorine institute pamphlet 6, piping systems for dry.

Because the chlorine manual only summarizes some of the information contained in. Chlorine institute pamphlet 6 rewrite chlorine institute pamphlet 6 the chlorine institute publishes pamphlets that provide guidance on the safe production, storage, transportation and handling of chlorine, a chemical broadly used in the manufacturer of plastics, specialty chemicals, agricultural chemicals and. The number of tanks should be the minimum which will satisfy. Flexible components brand chlorine transfer hose is ideal for tough, demanding applications such as chlorine, bromine, sodium hydroxide, sodium hypochlorite, sulfuric and hydrochloric acids, and other corrosive materials.

Only available in pdf format format details price pdf. At the beginning of section 11 selected references, complete information about the institute publications is provided. Provides basic information on useful physical and chemical properties, as well as compatible materials, handling systems and pertinent analytical procedures, emergency response. Download pamphlet 6 piping systems for dry chlorine ci. Omegaflex fabricates chlorine transfer hoses utilizing monel 400. Pdf pamphlet 6 piping systems for dry chlorine ci free.

Members of the chlorine institute are encouraged to test new gaskets and gasket materials following the procedures in pamphlet 95. As recommended by the chlorine institutes pamphlet 6 piping systems for dry chlorine, all pressurized piping should be seamless carbon steel, grade b. Chlorine chlor alkali valve figure numbers based on. This pamphlet demonstrates support of these principles.

984 422 490 1661 461 838 107 118 376 1644 1158 604 724 748 863 448 73 76 519 1037 458 1371 1096 1589 204 810 111 1124 932 1291 160 342 450 85 1294 1435 1138 351